Aristotle Air

Aristotle Air Units

Aristotle Air

Design Advantages

Constructed of durable, food-grade stainless steel, the Aristotle Air unit ventilator won’t rust or corrode. Its self-balancing design incorporates just six moving parts ensuring high reliability. Open mechanical access makes for quick filter changes and easy cleaning and maintenance.

Designed to fit the same footprint as an existing unit ventilator, an Aristotle Air unit operates with the facility’s existing HVAC systems, and can be installed in an average of 4 hours, using just 2 maintenance workers.

AA-FLR

The floor-mounted unit ventilator is designed to vertically supply air directly into the classroom and comfortably fit under-the-window. The unit is equipped with a fixed-plate energy recovery core coupled with heating and cooling coil(s) to more effectively heat your space, all while using less energy.

Features at a glance:
· Supply airflow up to 1250 cfm
· ERV or HRV energy recovery core
· Hot water/steam heating coil
· Chilled water/DX cooling coil
· UVGI rack system
· 100% economizer w/ modulating dampers
· Quiet operation

Download  Datasheet Download Technical Spec

AA-CLG

The ceiling-mounted unit ventilator is designed to horizontally supply air into the classroom via existing ducting. The unit is equipped with a fixed-plate energy recovery core coupled with heating and cooling coil(s) to more effectively heat your space, all while using less energy.

Features at a glance:
· Supply airflow up to 850 cfm
· HRV energy recovery core
· Hot/chilled water coils
· EC Motor
· UVGI rack system
· 100% economizer w/ modulating dampers
· Quiet operation

Download  Datasheet Download Technical Spec

AA-VRT

The floor-mounted vertical unit ventilator is designed to vertically supply air into the classroom via existing ducting. The unit is equipped with a fixed-plate energy recovery core coupled with heating and cooling coil(s) to more effectively heat your space, all while using less energy.

Features at a glance:
· Supply airflow up to 1250 cfm
· ERV or HRV energy recovery core
· Hot water/steam heating coil
· Chilled water/DX cooling coil
· UVGI rack system
· 100% economizer w/ modulating dampers
· Quiet operation

Download  Datasheet

Grand Traverse Area Catholic Schools

Mike Buell, Superintendent

“We converted two different wings of an old school to a new heating system. We replaced one large 4,000,000 BTU boiler with two 500,000 BTU high-efficiency units. This changeover took place during the heating season, after school hours, with no inconvenience whatsoever to our teachers or students. Because the heat recovery system was so efficient in utilizing the indoor temperature to sustain our comfort level, we were able to put off firing up the boilers for a full month. This, along with the energy efficiency of the units, saved us over 43% on our gas bills!”

More
Case Study